Source/Measure Unit for Functional Test, Multiple Ranges, 80 W

Output Ratings:

  • Voltage: 20 V / 15 V / 10 V / 6 V
  • Current: ±4 A / ±5 A / ±6.7 A / ± 8A
  • Power: Up to 80 W

Programming Accuracy (at 23°C ± 5°C after 30 minute warm-up. Applies from min. to max. program):

  • Voltage, 20 V, 15 V, 10 V, and 6 V ranges: 0.025% + 1.8 mV
  • Current, 4 A, 5 A, 6.7 A, and 8 A ranges: 0.04% + 1.4 mA

Output voltage ripple & noise (PARD) from 20 Hz to 20 MHz:

  • CV peak-to-peak: 15 mV
  • CVrms: 1.5 mV

Measurement Accuracy (at 23°C ± 5°C):

  • Voltage, 20 V range: 0.025% 1.8 mV
  • Current, 8 A range: 0.04% + 1.5 mA
  • Current, 100 mA range: 0.025% + 10 µA
  • Current, 1 mA range: 0.025% + 100 nA

Keysight N6786A – Ideal for advanced functional test

The ability to modulate the output up to 100 kHz along with 2-quadrant operation makes the N6786A a perfect fit for advanced functional test of a variety of devices such as DC/DC converters, power management units, power amplifiers, and power management ICs (PMICs).

  • Stimulate the input stage of your DUT with fast sourcing and waveforms up to 100 kHz using the advanced arbitrary waveform generation feature.
  • The output stage can be loaded down and measured with the electronic load capabilities of the N6786A, providing a total test solution

Source/Measure Unit for Functional Test, Multiple Ranges, 80 W

Output Ratings:

  • Voltage: 20 V / 15 V / 10 V / 6 V
  • Current: ±4 A / ±5 A / ±6.7 A / ± 8A
  • Power: Up to 80 W

Programming Accuracy (at 23°C ± 5°C after 30 minute warm-up. Applies from min. to max. program):

  • Voltage, 20 V, 15 V, 10 V, and 6 V ranges: 0.025% + 1.8 mV
  • Current, 4 A, 5 A, 6.7 A, and 8 A ranges: 0.04% + 1.4 mA

Output voltage ripple & noise (PARD) from 20 Hz to 20 MHz:

  • CV peak-to-peak: 15 mV
  • CVrms: 1.5 mV

Measurement Accuracy (at 23°C ± 5°C):

  • Voltage, 20 V range: 0.025% 1.8 mV
  • Current, 8 A range: 0.04% + 1.5 mA
  • Current, 100 mA range: 0.025% + 10 µA
  • Current, 1 mA range: 0.025% + 100 nA

Keysight N6786A – Ideal for advanced functional test

The ability to modulate the output up to 100 kHz along with 2-quadrant operation makes the N6786A a perfect fit for advanced functional test of a variety of devices such as DC/DC converters, power management units, power amplifiers, and power management ICs (PMICs).

  • Stimulate the input stage of your DUT with fast sourcing and waveforms up to 100 kHz using the advanced arbitrary waveform generation feature.
  • The output stage can be loaded down and measured with the electronic load capabilities of the N6786A, providing a total test solution

Why Buy from Instruhub:

  • Supplier of Keysight N6786A Source/Measure Unit, Double Wide, 80W, Multi-Range, N6780 SMU Series in Qatar
  • Best online prices for Keysight N6786A Source/Measure Unit, Double Wide, 80W, Multi-Range, N6780 SMU Series
  • Wide range of Keysight products available in Doha, Dukhan, Mesaieed (Umm Said)
  • Shipping at door with custom and duty included in price quote.

  • Instrument repair and calibration services provided.

  • InstruHub also provides DG Cargo service with as goods with Lithium Ion Batteries.

Similar products